Main gas NPT connections

e. Use joint compound/thread sealant, properly threaded pipes and careful assembly procedure so that there is no cross threading, etc., which can cause damage or leakage.
f. Apply light pressure only at wrench flats (see Figure 1) to avoid damage to control body, which can result in leakage or malfunction of control. Do not apply pressure to top casting or plastic cover.
Main gas (outlet only) and/or *side outlet tubing connection g. Square off end of tubing and remove burrs. h. Inflatable Theme Park Slip gland and ferrule over tubing. I. Insert tubing into the outlet until it bottoms, slide ferrule and gland into place and turn finger tight. Do not use joint compound. j. Use a wrench to tighten gland about one turn beyond finger tight. (*if side outlet model, do not rotate outlet in its threads to avoid possible leakage.)